What to look for in Division 11 Equipment

Commonly required items in Div 11 specs:

  • Equipment schedule with model numbers cross-referenced to drawings
  • Utility rough-in drawings (gas, electric, plumbing, drain for each piece)
  • Equipment cut sheets with full dimensional data (plan, elevation, utility connection locations)
  • NSF/ANSI listing documentation for each foodservice item
  • UL and AGA certification numbers
  • Warranty documentation (compressor, parts, labor durations)
  • Refrigerant type and charge weight
  • Noise/sound data (dBA at specified distance) where specified
  • Seismic anchorage details for equipment over 400 lbs (IBC Chapter 13)
  • Energy compliance data (ASHRAE 90.1, ENERGY STAR verification)
  • Maintenance and service access clearance diagrams
  • Start-up and commissioning procedures for complex equipment (combi ovens, blast chillers, conveyor dishwashers)

How severe is it?

Default grade: Fix and Resubmit. The sub completes the package and resubmits before the PM can fully review.

Deviation Check assigns a default per category and escalates or de-escalates based on the spec, always showing its reasoning. See the Division 11 severity rules.

What the PM should do

Stamp the submittal Revise and Resubmit. Mark the deviation, return the relevant spec passage as a redline, and have the sub correct and re-send before fabrication or installation.

Frequently asked questions

What utility rough-in and certification documents must be included in a complete Division 11 Equipment submittal package?

A complete package includes utility rough-in drawings showing gas, electric, plumbing, and drain for each piece. NSF/ANSI listing documentation is required for every foodservice item. UL and AGA certification numbers must be present. Equipment cut sheets with full dimensional data - plan, elevation, and utility connection locations - are required. Refrigerant type and charge weight, plus noise/sound data in dBA where specified, round out the technical documentation.

Which Division 11 Equipment items require seismic anchorage details and commissioning procedures in the submittal?

Equipment over 400 lbs requires seismic anchorage details per IBC Chapter 13. Complex equipment types - combi ovens, blast chillers, and conveyor dishwashers - require start-up and commissioning procedures. Maintenance and service access clearance diagrams are also required. An equipment schedule with model numbers cross-referenced to drawings ties the package together. Missing any of these items makes the package unreviewable as submitted and results in a Fix and Resubmit finding.

View this page as Markdown for LLMs and note-taking.