# Missing Certification or Compliance Documentation in Division 10 Specialties submittals

> Source: https://deviationcheck.com/divisions/10-specialties/missing-certification/

A required listing, test report, certification, or compliance document is absent from the submittal package.

## What to look for in Division 10 Specialties

Required certifications in specialties submittals:
- **ADA/ICC A117.1 compliance documentation** for all accessible toilet accessories, signage, and compartments
- **UL listing** for fire extinguisher cabinets (UL 2017 or applicable standard)
- **NFPA 10 compliance** for fire extinguisher type, size, and placement
- **ASTM E84 test report** (surface burning characteristics - flame spread and smoke development) for partition materials and wall protection
- **ASTM A480 compliance** for stainless steel accessories and partitions (surface finish, tolerances)
- **ANSI Z535 compliance** for safety signage (colors, symbols, format)
- **BHMA (Builders Hardware Manufacturers Association)** certification for hardware on toilet partitions
- **GREENGUARD or GREENGUARD Gold certification** when spec requires low-emitting materials
- **SCAQMD Rule 1168 VOC compliance** for adhesives and sealants used in installation
- **AMCA certified ratings** for louver performance (free area, water penetration, pressure drop)
- **Product data sheets** with physical and mechanical properties for each specified product

## Severity

Default grade: Fix and Resubmit. Escalates to Blocker when the missing document is a code or life-safety requirement (UL listing, fire rating).