# Division 08: Openings submittal deviations

> Source: https://deviationcheck.com/divisions/08-openings/
> Deviation Check - AI submittal review for General Contractors (Aliso LLC).

Division 08 covers openings in commercial construction: doors, frames, finish hardware, glass, glazing, storefronts, curtain walls, and specialty doors. Common CSI sections submitted for review:

## Common Division 08 CSI sections

- 08 11 13 - Hollow Metal Doors and Frames
- 08 11 16 - Aluminum Doors and Frames
- 08 14 00 - Wood Doors
- 08 31 13 - Access Doors and Frames
- 08 33 23 - Overhead Coiling Doors
- 08 34 73 - Sound Control Door Assemblies
- 08 36 13 - Sectional Doors
- 08 41 13 - Aluminum-Framed Entrances and Storefronts
- 08 44 13 - Glazed Aluminum Curtain Walls
- 08 51 13 - Aluminum Windows
- 08 62 00 - Unit Skylights
- 08 71 00 - Door Hardware (finish hardware)
- 08 80 00 - Glazing
- 08 88 00 - Special Function Glazing

## The six deviation categories in Division 08 Openings

### Manufacturer or Product Substitution (default grade: Blocker)

The submittal proposes a different manufacturer or product than the spec names, without an approved or-equal or substitution request.

Div 08 specs name door, frame, hardware, and glazing system manufacturers. Look for:
- Door manufacturer substitutions (Steelcraft/Allegion, Ceco/ASSA ABLOY, Republic Doors, Mesker)
- Wood door manufacturer substitutions (VT Industries, Masonite Architectural, Marshfield, Oshkosh)
- Hardware manufacturer substitutions (Schlage/Allegion, Sargent/ASSA ABLOY, Hager, Best/dormakaba)
- Closer manufacturer substitutions (LCN, Norton, dormakaba, SARGENT)
- Exit device manufacturer substitutions (Von Duprin, Precision, Sargent)
- Aluminum entrance/storefront manufacturer substitutions (Kawneer/Arconic, YKK AP, Tubelite, Oldcastle/C.R. Laurence)
- Curtain wall manufacturer substitutions (Kawneer, YKK AP, Wausau, Vitro Architectural Glass)
- Glass manufacturer substitutions (Viracon, Oldcastle, Guardian, PPG, AGC)
- Overhead door manufacturer substitutions (Overhead Door Corp, Wayne Dalton, Amarr, Cookson)

Full guide: https://deviationcheck.com/divisions/08-openings/manufacturer-substitution/

### Performance Specification Gap (default grade: Blocker)

A measurable performance property in the submittal (rating, capacity, tolerance, efficiency) does not meet what the spec requires.

Key performance parameters in Div 08 submittals:
- **Fire rating** (20/45/60/90/180 minute per UL/WHI/Intertek tested assembly)
- **STC (Sound Transmission Class)** rating for acoustic doors and assemblies
- **U-value** (thermal transmittance, Btu/hr-sf-F) for windows, curtain wall, storefronts
- **SHGC (Solar Heat Gain Coefficient)** per NFRC rating
- **VLT (Visible Light Transmittance)** percentage
- **Air infiltration rate** (cfm/sf at test pressure per ASTM E283)
- **Water penetration resistance** (psf per ASTM E331 or AAMA 501.1)
- **Structural wind load** (psf per ASTM E330, design pressure)
- **Forced entry resistance** (per ASTM F588 where specified)
- **Impact resistance** (ANSI Z97.1 and CPSC 16 CFR 1201 for safety glazing)
- **Bullet resistance** (UL 752 levels where specified)
- **Blast resistance** (GSA/ISC or ASTM F2927 where specified)
- **Door gauge** (16ga, 18ga, 20ga for hollow metal)
- **Frame gauge** (16ga, 14ga for hollow metal)
- **Glass makeup** (monolithic, laminated, insulating, tempered, heat-strengthened)
- **Curtain wall deflection** (L/175, L/240, or as specified)

Full guide: https://deviationcheck.com/divisions/08-openings/performance-specification-gap/

### Missing Certification or Compliance Documentation (default grade: Fix and Resubmit)

A required listing, test report, certification, or compliance document is absent from the submittal package.

Required certifications in Div 08 submittals:
- **UL/WHI fire-rated assembly listing** (door + frame + hardware as complete assembly)
- **NFPA 80** compliance for fire door assemblies (inspection, testing, maintenance)
- **BHMA/ANSI hardware certification** (A156 series standards for each hardware type)
- **DHI (Door and Hardware Institute)** hardware consultant certification
- **ADA compliance** documentation for accessible openings (ANSI A117.1)
- **AAMA certifications** for windows and curtain wall (AAMA 501, 502, 503 test standards)
- **NFRC certification** for U-value, SHGC, VLT ratings
- **IGCC/IGMA certification** for insulating glass unit seal durability
- **Safety glazing certification** per building code (ANSI Z97.1, CPSC 16 CFR 1201)
- **Florida Product Approval** or Miami-Dade NOA (for wind-borne debris zones)
- **ENERGY STAR** certification where specified
- **ICC-ES ESR** for proprietary frame systems or anchoring methods
- **Seismic certification** for curtain wall drift accommodation (IBC)

Full guide: https://deviationcheck.com/divisions/08-openings/missing-certification/

### Aesthetic Deviation (default grade: Fix and Resubmit)

A visible attribute (color, finish, texture, profile) differs from the spec or the architect-approved sample.

- Door finish (paint color, wood species/veneer, laminate pattern, stain)
- Hardware finish per BHMA designation (US26D satin chrome, US32D satin stainless, US10B oil-rubbed bronze, etc.)
- Glass type appearance (tint color, reflectivity, spandrel color and opacity)
- Aluminum frame finish (anodized class/color, Kynar/PVDF paint color per RAL or custom)
- Curtain wall mullion profile (cap vs structural silicone glazed, exposed width)
- Door lite kit configuration (full lite, half lite, narrow lite, vision panel size)

Full guide: https://deviationcheck.com/divisions/08-openings/aesthetic-deviation/

### Detail or Installation Mismatch (default grade: Fix and Resubmit)

The submitted detail, dimension, anchorage, or installation method differs from what the spec or drawings require.

- **Door gauge** lighter than spec (20ga where 18ga specified)
- **Frame gauge** lighter than spec (18ga where 16ga specified)
- **Hinge count or weight rating** below spec (3 vs 5 knuckle, bearing vs plain)
- **Closer size** (ANSI size 1-6) does not match door weight/width
- **Lockset function** mismatch (classroom vs storeroom vs passage vs privacy)
- **Glazing thickness or makeup** differs (monolithic where laminated specified)
- **Curtain wall mullion depth** differs (affects structural capacity and thermal performance)
- **Thermal break** vs non-thermal-break frame (affects U-value compliance)
- **Door undercut** dimension differs from spec (affects fire rating and ADA)
- **Weatherstripping type** differs (compression vs magnetic vs interlocking)
- **Threshold type** differs (ADA compliant height, material)
- **Panic hardware** type or operation differs (rim vs mortise vs CVR)
- **Auto operator** type differs (low energy vs full power, activation method)

Full guide: https://deviationcheck.com/divisions/08-openings/detail-installation-mismatch/

### Submittal Package Incompleteness (default grade: Fix and Resubmit)

A required submittal element (cut sheet, schedule, calculation, sample) is missing, leaving the package unreviewable as submitted.

Commonly required items in Div 08 specs:
- Hardware schedule cross-referenced to door schedule (every opening with hardware set)
- Keying schedule (master key system, construction keying, final keying)
- Curtain wall shop drawings with structural analysis
- Curtain wall thermal analysis (condensation resistance per AAMA 1503)
- Door/frame/hardware templates (shop drawings showing prep locations)
- Finish samples (hardware finishes, frame finishes)
- Glass mock-up details (for curtain wall projects)
- Fire-rated assembly documentation (complete UL/WHI listing with all components)
- Warranty documentation (hardware, glass, curtain wall system, finish)
- Wind load analysis for curtain wall and storefront
- Structural engineering for curtain wall anchorage
- ADA compliance verification for each accessible opening

---

Full guide: https://deviationcheck.com/divisions/08-openings/submittal-package-incompleteness/

## How Division 08 deviations are graded

- **Fire-rated assembly listing missing or mismatched:** BLOCKER (life-safety, NFPA 80, IBC)
- **Hardware function mismatch on fire/egress door:** BLOCKER (life-safety, means of egress)
- **Safety glazing omission where code requires:** BLOCKER (building code, injury risk)
- **U-value or SHGC exceeding energy code maximum:** BLOCKER (ASHRAE 90.1/IECC violation)
- **Wind load rating below design pressure:** BLOCKER (structural, building code)
- **Missing ADA compliance on accessible opening:** BLOCKER (ADA/ANSI A117.1 requirement)
- **Exit device missing or wrong type on required egress door:** BLOCKER (IBC means of egress)
- **Door/frame gauge lighter than spec:** FIX_AND_RESUBMIT (durability, security)
- **Hardware finish mismatch:** FIX_AND_RESUBMIT (aesthetic)
- **Glass VLT or appearance mismatch:** FIX_AND_RESUBMIT (aesthetic, architect's design intent)
- **Missing keying schedule:** FIX_AND_RESUBMIT (coordination, cannot finalize without it)
- **Curtain wall deflection exceeds spec limit:** BLOCKER (glass breakage risk)
- **Missing curtain wall structural analysis:** BLOCKER (cannot verify adequacy)