# Missing Certification or Compliance Documentation in Division 04 Masonry submittals

> Source: https://deviationcheck.com/divisions/04-masonry/missing-certification/

A required listing, test report, certification, or compliance document is absent from the submittal package.

## What to look for in Division 04 Masonry

Required certifications in masonry submittals:
- **TMS 402/602** compliance (Building Code Requirements and Specification for Masonry Structures)
- **ASTM C90** test reports for concrete masonry units (compressive strength, absorption, moisture content)
- **ASTM C62/C216/C652** test reports for brick (compressive strength, absorption, saturation coefficient, IRA)
- **ASTM C270** mortar compliance (property or proportion method)
- **ASTM C476** grout compliance
- **ASTM C1019** grout prism test reports
- **Mill certificates** for masonry reinforcing steel
- **Fire resistance documentation** (UL assembly listing or TMS 216.1 calculated rating)
- **Seismic compliance** documentation (IBC/ASCE 7, TMS 402 seismic provisions)
- **ASTM C97/C99/C170/C880** test reports for natural stone (absorption, flexural, compressive)
- **LEED documentation** (recycled content for CMU, regional materials)
- **Efflorescence test results** (ASTM C67 for brick, ASTM C1372 for CMU)

## Severity

Default grade: Fix and Resubmit. Escalates to Blocker when the missing document is a code or life-safety requirement (UL listing, fire rating).