# Division 04: Masonry submittal deviations

> Source: https://deviationcheck.com/divisions/04-masonry/
> Deviation Check - AI submittal review for General Contractors (Aliso LLC).

Division 04 covers masonry construction in commercial buildings: concrete masonry units (CMU), brick, stone, mortar, grout, reinforcing, and related accessories. Common CSI sections submitted for review:

## Common Division 04 CSI sections

- 04 05 00 - Common Work Results for Masonry
- 04 05 13 - Masonry Mortaring
- 04 05 16 - Masonry Grouting
- 04 05 19 - Masonry Anchorage and Reinforcing
- 04 05 23 - Masonry Accessories (ties, anchors, flashing, weeps, control joints)
- 04 20 00 - Unit Masonry
- 04 21 13 - Brick Masonry
- 04 22 00 - Concrete Unit Masonry (CMU)
- 04 22 23 - Reinforced Unit Masonry
- 04 23 00 - Glass Unit Masonry
- 04 27 00 - Multiple-Wythe Unit Masonry
- 04 40 00 - Stone Assemblies
- 04 42 00 - Exterior Stone Cladding
- 04 43 00 - Stone Masonry
- 04 72 00 - Cast Stone Masonry

## The six deviation categories in Division 04 Masonry

### Manufacturer or Product Substitution (default grade: Blocker)

The submittal proposes a different manufacturer or product than the spec names, without an approved or-equal or substitution request.

Masonry specs name specific unit manufacturers, mortar producers, and accessory suppliers. Look for:
- CMU manufacturer substitutions (Oldcastle/CRH, Basalite, Angelus Block, Trenwyth, QUIKRETE)
- Brick manufacturer substitutions (Boral, General Shale, Acme Brick, Glen-Gery, Endicott)
- Natural stone supplier changes (quarry source matters for color and physical properties)
- Cast stone manufacturer substitutions (Arriscraft, Indiana Limestone, US Precast)
- Mortar manufacturer substitutions (Spec Mix, Quikrete, Lehigh Hanson, US Mix)
- Masonry accessory substitutions for ties, anchors, flashing (Hohmann & Barnard, Wire-Bond, Blok-Lok, Heckmann)
- Through-wall flashing manufacturer changes (Sandell, Mortar Net, Hohmann & Barnard)
- Masonry sealer/repellent manufacturer changes (Prosoco, Sikagard, Sto)

Full guide: https://deviationcheck.com/divisions/04-masonry/manufacturer-substitution/

### Performance Specification Gap (default grade: Blocker)

A measurable performance property in the submittal (rating, capacity, tolerance, efficiency) does not meet what the spec requires.

Key performance parameters in masonry submittals:
- **CMU compressive strength** (f'm prism strength, unit strength per ASTM C90: typically 1900-3000 psi for load-bearing)
- **CMU weight class** (normal weight ~135 pcf, medium weight ~105-125 pcf, lightweight ~85-105 pcf)
- **CMU moisture content** (Type I moisture-controlled vs Type II non-moisture-controlled)
- **Brick compressive strength** (psi per ASTM C62, C216, or C652)
- **Brick absorption rate** (% per ASTM C67, affects bond and freeze-thaw durability)
- **Brick grade** (SW Severe Weathering, MW Moderate Weathering per ASTM C62/C216)
- **Mortar type** (M, S, N, O per ASTM C270 - property vs proportion specification)
- **Grout strength** (f'g psi at 28 days per ASTM C476)
- **Reinforcing steel grade** (Grade 60 per ASTM A615/A706)
- **Stone flexural strength** (modulus of rupture per ASTM C99/C880)
- **Stone absorption rate** (% per ASTM C97)
- **Fire rating** of masonry assembly (hours per UL/WHI listing or calculated per TMS 216)
- **STC rating** of masonry assembly
- **Thermal resistance** (R-value of insulated masonry assembly)

Full guide: https://deviationcheck.com/divisions/04-masonry/performance-specification-gap/

### Missing Certification or Compliance Documentation (default grade: Fix and Resubmit)

A required listing, test report, certification, or compliance document is absent from the submittal package.

Required certifications in masonry submittals:
- **TMS 402/602** compliance (Building Code Requirements and Specification for Masonry Structures)
- **ASTM C90** test reports for concrete masonry units (compressive strength, absorption, moisture content)
- **ASTM C62/C216/C652** test reports for brick (compressive strength, absorption, saturation coefficient, IRA)
- **ASTM C270** mortar compliance (property or proportion method)
- **ASTM C476** grout compliance
- **ASTM C1019** grout prism test reports
- **Mill certificates** for masonry reinforcing steel
- **Fire resistance documentation** (UL assembly listing or TMS 216.1 calculated rating)
- **Seismic compliance** documentation (IBC/ASCE 7, TMS 402 seismic provisions)
- **ASTM C97/C99/C170/C880** test reports for natural stone (absorption, flexural, compressive)
- **LEED documentation** (recycled content for CMU, regional materials)
- **Efflorescence test results** (ASTM C67 for brick, ASTM C1372 for CMU)

Full guide: https://deviationcheck.com/divisions/04-masonry/missing-certification/

### Aesthetic Deviation (default grade: Fix and Resubmit)

A visible attribute (color, finish, texture, profile) differs from the spec or the architect-approved sample.

- CMU color, texture, and surface finish (smooth, split-face, scored, ground-face, burnished, fluted)
- Brick color, texture, size, and coursing pattern (running bond, stack bond, Flemish bond)
- Natural stone color, finish (polished, honed, thermal/flamed, bush-hammered, sandblasted), and veining
- Cast stone color match to natural stone
- Mortar joint color (natural, colored to match/contrast)
- Mortar joint profile (concave, V-joint, raked, weathered, flush)
- Control joint and expansion joint sealant color

Full guide: https://deviationcheck.com/divisions/04-masonry/aesthetic-deviation/

### Detail or Installation Mismatch (default grade: Fix and Resubmit)

The submitted detail, dimension, anchorage, or installation method differs from what the spec or drawings require.

- **Bond pattern** differs from drawings (running bond vs stack bond vs other)
- **Mortar joint thickness** differs from spec (typically 3/8" for CMU, 3/8" for brick)
- **Reinforcing bar size or spacing** differs from structural drawings
- **Grout pour height** or lift height exceeds TMS 602 limits
- **Wall tie type or spacing** differs (adjustable vs non-adjustable, horizontal/vertical spacing)
- **Through-wall flashing** type or termination detail differs
- **Weep hole spacing** or type differs (open head joint, wicks, tubes)
- **Control joint spacing** differs from spec or structural drawings
- **Expansion joint location** differs (critical for brick to accommodate thermal movement)
- **Lintel size or bearing length** differs from structural design
- **Shelf angle location or size** differs
- **Veneer anchor type or embedment** differs

Full guide: https://deviationcheck.com/divisions/04-masonry/detail-installation-mismatch/

### Submittal Package Incompleteness (default grade: Fix and Resubmit)

A required submittal element (cut sheet, schedule, calculation, sample) is missing, leaving the package unreviewable as submitted.

Commonly required items in Div 04 specs:
- CMU product data with ASTM C90 test results
- Brick samples and product data with ASTM C216 test results
- Natural stone samples with ASTM test results (C97, C99, C170, C880)
- Mortar mix design or product data per ASTM C270
- Grout mix design per ASTM C476
- Masonry reinforcing steel mill certificates
- Wall tie and anchor product data with pull-out test results
- Through-wall flashing product data and installation details
- Shop drawings for reinforced masonry (bar placement, grouting plan)
- Stone cladding shop drawings with anchorage details
- Cast stone shop drawings with joint layout
- Masonry prism test plan (f'm testing per ASTM C1314)
- Sealer/repellent product data and mock-up plan
- Cold weather and hot weather masonry plan

---

Full guide: https://deviationcheck.com/divisions/04-masonry/submittal-package-incompleteness/

## How Division 04 deviations are graded

- **CMU compressive strength below spec f'm:** BLOCKER (structural capacity per TMS 402)
- **Brick grade below weathering requirement (MW where SW specified):** BLOCKER (freeze-thaw durability)
- **Mortar type below spec (Type N where Type S specified):** BLOCKER (structural capacity and weather resistance)
- **Grout strength below spec:** BLOCKER (structural capacity for reinforced masonry)
- **Reinforcing grade below spec:** BLOCKER (structural per TMS 402)
- **Missing fire rating documentation for rated assembly:** BLOCKER (life-safety)
- **Missing seismic compliance for reinforced masonry:** BLOCKER (IBC)
- **Wall tie type or spacing non-compliant with TMS 402:** BLOCKER (structural connection of wythes)
- **Through-wall flashing omitted where spec requires:** BLOCKER (water infiltration, structural damage)
- **CMU weight class mismatch (lightweight where normal weight specified for structural):** BLOCKER if structural, FIX_AND_RESUBMIT if non-structural
- **Brick color or texture mismatch:** FIX_AND_RESUBMIT (aesthetic)
- **Mortar joint profile mismatch:** FIX_AND_RESUBMIT (aesthetic)
- **Missing efflorescence test results:** FIX_AND_RESUBMIT (quality assurance)